产品展示|Products
AQ700系列多参数水质取样器
AQ700 Multi-parameter Probes
The AQ700 from Teledyne Isco comprises up to six different sensors in a single sonde, for a total of ten possible measured parameters. All AQ700 data stored by the sampler or logger is ready for retrieval, reporting, and graphing using Teledyne Isco Flowlink® software.
The AQ700's ease-of-use design includes direct USB connection to your computer, real-time data viewing, and LED indicators for operating status.
- AQ702 Multi-parameter Probe
Up to nine water quality parameters. Reliable data. Unsurpassed technology. - AQ703 Multi-parameter Probe
Up to ten water quality parameters including turbidity. Reliable data. Unsurpassed technology.
AQ703 Multi-parameter Probe
Up to ten water quality parameters including turbidity. Reliable data. Unsurpassed technology.
| Depending on your monitoring requirements, the AQ703 can operate with any of the following Teledyne Isco instruments:
• 6712 Series Samplers
Applications
|
![]() |
Specifications
| Dimensions (w/ weighted sensor guard): | Length 16 " (40.64 cm); Diameter 2.95 " (7.49" cm) |
| Weight (w/ weighted sensor guard): | In air 5.2 lbs (2.3 kg); In water 1.2 lbs (1.45 kg) |
| Materials: | PVC, 316 SST, Acetal, Polycarbonate, PTFE, Viton, Glass, Graphite, Silicone, Urethane, Platinum, Acrylic |
| Temperature: | Operating 23 to 122 °F (-5 to 50 °C); Storage 14 to 122 °F (-10 to 50 °C) |
| Power: | 12VDC Supplied by connected sampler or flow meter, or USB connection to computer |
| Communication: | SDI-12 Protocol and RS-232 |
| Temperature: | Operating 23 to 122 °F (-5 to 50 °C); Storage 14 to 122 °F (-10 to 50 °C) |
| Power: | 12VDC Supplied by connected sampler or flow meter, or USB connection to computer |
| Communication: | SDI-12 Protocol and RS-232 |
| Temperature: | Measurement range -5 to 50 °C (23 to 122 °F); Resolution 0.01 °C (0.01 °F); Accuracy ±0.1 °C |
| Optical Dissolved Oxygen (DO): | Compensated for temperature and salinity; Measurement range 0 to 20 mg/L; Resolution 0.01 mg/L; Linearity ±0.2 mg/L. (Alternative parameter - % Saturation) |
| Conductivity: | Specific Conductance corrected for temperature. Measurement range 0 to 100,000 µS/cm. Resolution 0.1 µS/cm (0 - 999.9), 1 µS/cm (1000 to 9,999), 10 µS/cm (10,000 to 99,990); Linearity ±1% of reading ±1 µS/cm. Additional Parameters - Salinity, Total Dissolved Solids (TDS) |
| pH: | Corrected for temperature. Measurement range 0 to 14 pH units. Resolution 0.01 pH units; Linearity ±0.2 pH units |
| Oxidation Reduction Potential (ORP): | Measurement range -999 to 999 mV; Resolution 1 mV; Linearity ±20 mV |
| Depth: | Measurement range 0 to 15 m (0 to 49 ft); Resolution 0.01 m (0.01 ft); Linearity ±0.05 m |
| Turbidity: | Measurement range 0 to 3,000 NTU; Resolution 0.1 (0 - 999.9 NTU), 1 (1000 to 3000 NTU); Linearity ±2% of reading ± 2 NTU |